Utilities · IPPs · Latin America & Caribbean

Score every sync attempt before the breaker closes.

SyncGuard overlays AI on your existing synchronization panel. 0–100 quality score before every close. Governor and AVR fingerprinting over time.

SyncGuard was born from direct experience black-starting 8GW of Pratt & Whitney and Siemens utility gas turbines. We overlay AI on Deep Sea, ComAp, and Woodward panels to score sync quality and detect governor and AVR degradation before it becomes a grid event.

🔆
Photo: Gas Turbine / Synchronization Panel
Product photo goes here

We have black-started 8GW of utility turbines. SyncGuard was born from that work.

Designing cranking sets to black-start Pratt & Whitney and Siemens gas turbines at utility scale taught us where synchronization failures come from. Governor droop mismatches, AVR response lag, frequency overshoot on load acceptance — patterns that repeat across every turbine fleet.

SyncGuard overlays AI on Deep Sea, ComAp, and Woodward synchronization panels. It scores every sync attempt 0–100 before the breaker closes, and it builds a fingerprint of your governor and AVR response over time.

Targeted at Latin American and Caribbean independent power producers where grid reliability challenges make synchronization quality critical.

Sync quality score 0–100 before every breaker close
Voltage match, frequency match, phase angle, and ROCOF evaluated in real time. Score calculated before the breaker closes — not after a bad sync damages equipment.
Governor response fingerprinting
Tracks your governor's load acceptance and load rejection response over time. Detects droop changes, fuel system degradation, and actuator wear before they affect grid stability.
AVR drift detection
Automatic Voltage Regulator response fingerprinting. Detects gain changes, setpoint drift, and response time degradation — leading indicators of excitation system issues.

Works with your existing sync panel.

Compatible PanelsDeep Sea Electronics DSE · ComAp InteliGen/InteliSys · Woodward SPM-D · Generic analog sync panels
Measurements3-phase voltage (both sides) · Frequency · Phase angle · dV/dt · df/dt (ROCOF)
Sync Score0–100 calculated pre-close · Voltage deviation · Frequency deviation · Phase angle · Rate of change
Governor AnalysisLoad step response · Droop coefficient trending · Fuel actuator response time
AVR AnalysisVoltage recovery time · Overshoot percentage · Settling time · Reactive power response
Black Start SupportCranking set monitoring · Island mode detection · Frequency build-up analysis
Data LoggingEvery sync attempt logged · Full waveform capture on bad sync · AWS cloud archival
LanguagesEnglish · Spanish · Portuguese (Latin America / Caribbean focus)
MarketsDominican Republic · Puerto Rico · Colombia · Venezuela · Guatemala · Jamaica · Trinidad
Pratt & Whitney gas turbinesSiemens gas turbinesGE LM-seriesCaterpillar diesel gen-setsCummins diesel gen-setsWartsila dual-fuelMAN dieselDiesel gen-sets (any make)Gas reciprocating engines
🔆
Turbine / Sync Panel Photo
Gas turbine, generator, or synchronization panel

Ready to improve your synchronization quality?

SyncGuard overlays non-invasively on your existing sync panel. No control system changes. Spanish and Portuguese language support for Latin American deployments.