Hospitals · Data Centers · High-Rise · Municipalities

Life safety equipment that fails when you need it most.

SafeGuard monitors fire pumps, emergency generators, and standby systems 24/7 — and predicts failures before the next emergency.

Fire pumps, emergency generators, elevator motors, and ATS units sit idle for months. SafeGuard monitors them continuously and generates automated NFPA 110 and NFPA 25 compliance reports.

🔴
Photo: Fire Pump Room / Emergency Generator
Product photo goes here

Life safety systems sit idle for months. Failures are invisible until they matter most.

Fire pumps, emergency generators, elevator motors, and ATS units run monthly tests but spend 99% of their time waiting. Conventional testing catches obvious failures. SafeGuard catches the subtle degradation that conventional testing misses — the bearing that has 3 more months, the battery that won't hold a full charge, the fuel that's beginning to degrade.

NFPA 110 and NFPA 25 compliance documentation generated automatically. Every test cycle logged with AI health assessment.

Fire pump health — NFPA 25 compliance
Motor current, pressure, flow rate, and vibration during every test cycle. Trending analysis catches degradation months ahead.
Emergency generator predictive maintenance
Engine health, battery condition, fuel quality, coolant temperature, and load test performance. Automated NFPA 110 compliance reporting.
Battery health prediction
Charge/discharge trending, internal resistance measurement, capacity fade detection. Predicts replacement need 60–90 days ahead.

Built for life-critical reliability.

Edge HardwareNVIDIA Jetson Orin NX · Redundant power supply · NEMA 4X enclosure
Fire Pump MonitoringMotor current (3-phase) · Discharge pressure · Suction pressure · Vibration · Run time logging
Generator MonitoringEngine runtime · Load percentage · Battery voltage/current · Fuel level · Coolant temp · Oil pressure
Battery TestingCharge cycle analysis · Internal resistance · Capacity trending · Cell voltage balancing
ATS MonitoringTransfer time · Contact wear · Voltage/frequency on both sources · Transfer event logging
ComplianceNFPA 110 · NFPA 25 · Automated test reports · Inspection-ready documentation
AlertsSMS · Email · Push notification · Facility manager + service contractor
IntegrationBACnet/IP · Modbus · Direct I/O · AWS cloud archival
Fire pumps (electric & diesel)Emergency generatorsATS unitsElevator motorsJockey pumpsTransfer switchesBattery backup systemsCooling tower motorsSmoke control fans
🔴
Fire Pump Photo
Fire pump room or motor close-up
Generator Photo
Emergency generator / ATS panel

Ready to protect your life safety systems?

Start with your most critical equipment. We instrument it, establish baseline health scores, and you have compliance-ready documentation from day one.