Your pump won’t fail on a convenient day.
The bearing has been warning you for weeks.

Pumps, VFDs, motors — the workhorses nobody watches until the water stops.

Rotating equipment telegraphs its failures. Bearing wear shows up as a slow rise in vibration weeks before the seizure; cavitation chews an impeller long before flow collapses; a tired motor pulls a little more current every day. Veritas Data designs and builds monitoring that reads what your VFDs and meters already know over Modbus — read-only — and adds vibration sensing on the bearings, where the story really lives. So the fix happens on your schedule, not the pump’s.

Modbus RTU & TCP reads your drives, read-onlyVibration sensors on the bearing housingsCustom-built to your pumps, not off a shelf
By the time a pump is loud enough to hear across the plant room — or trips on overload — the failure is already expensive. The signals were there for weeks.
  • Climbing vibration. Bearing wear and misalignment show up as a slow vibration trend long before seizure — the textbook early warning on any rotating machine.
  • Cavitation. A pump that sounds like it’s pumping gravel is eating its own impeller — collapsing vapor bubbles pit the metal and drag efficiency down with it.
  • Creeping current. Same flow, more amps: wear, clogging, or a motor fighting something it shouldn’t be. Nobody reads the drive display until something trips.
  • The standby nobody exercises. The duty pump gets the attention; the standby fails silently — and you find out the one moment it’s actually needed.
Why it matters

A cheap machine guarding expensive consequences.

The pump itself is rarely the loss. It’s what the pump was doing: the condenser loop that takes a chiller down with it, the booster that leaves upper floors dry, the sump that floods an electrical room, the transfer line that stops production. Add emergency labor, overnight parts, and secondary damage, and a failure that had been vibrating for a month ends up costing many times the early fix.

Descriptive → Predictive → Prescriptive

What we build for your pumps.

The same analytics spine behind every Veritas system, engineered around your rotating equipment.

01 · Descriptive

What’s happening

A continuous, read-only picture of every pump — from the drives you already own, and sensors we add where the data doesn’t exist yet.

  • Modbus from VFDs & meters
  • Vibration on bearing housings
  • Flow & pressure trends
  • Runtime & starts per pump
02 · Predictive

What’s coming

The trend that turns a maintenance surprise into a calendar item — flagged while the process still looks normal.

  • Vibration-trend early warning
  • Learned baseline per pump
  • Cavitation signatures
  • Current-draw anomalies
03 · Prescriptive

What to do

What to fix, how soon, and the recorded data to justify the work order before the failure.

  • Bearing inspection flags
  • Alignment & lubrication checks
  • Repair timing windows
  • Evidence for the fix
Interactive example

What we’d put in front of you.

One condenser-water pump, with sample data — not a live system. Drive the story with the scenario buttons: watch the vibration trend, the projection of where it’s heading, and when the early warning fires versus when a fixed alarm would. That gap is the point.

Scenario:
Pump 02 · Condenser water loop SAMPLE DATA
--:--:--
Bearing vibration · 30-day trend + projection
0.11in/s
watch > 0.30 in/s today → projected fixed alarm fires here
No threshold crossing projected at the current trend.
OKWATCHACT
Recommended action

96health score
Example dashboard · sample data for illustration · your build reflects your pumps and your alert thresholds
How it connects

Onto the drives and meters you already run.

  • Reads your drives, read-only

    A Modbus RTU/TCP client that polls the VFDs, soft starters, and power meters you already own — it never writes a register or changes a setting.

  • Vibration where it matters

    Sensors on the bearing housings, wired to our gateway in parallel — nothing touches the starter, the drive parameters, or the control circuit.

  • One dashboard, every site

    Duty and standby, one plant room or a whole portfolio — every pump reads from a single view, with its own learned baseline.

It never touches your controls.

We read the drive, add our own sensors, and recommend — your starters, VFD settings, and interlocks stay exactly as your team configured them. That’s the line that lets a risk-averse plant say yes.

// read-only · parallel sensors · controls untouched
Who it's built for

Anywhere a pump is never just a pump.

Plants & process

Where the pump is the cooling loop, the transfer line, the product — and an unplanned stop is measured per hour.

Commercial buildings

Condenser water, chilled water, boosters, sumps — the rotating support cast behind every comfort complaint and every flooded room.

Facility & service teams

Contractors and operators who’d rather schedule a bearing than explain a flood — with the data to back the work order.

Catch the bearing while it’s a line item.

Tell us what you pump — we’ll design the monitoring for it.